Automatic External Defibrillator

Model: BM-AED-2000

Fill in the form to get more product information

Product Introduction

Product Description

Standard configuration: AED/Manual/ECG

Optional: SPO2, NIBP, ETCO2, PACER, TOUCH SCREEN

Technical Specifications

• Display

Screen Type: High-resolution display.

Screen size: 8 inches LCD.

Sweep Speed: 25mm/sec.

Information: Heart Rate, Lead/Pads, Alarm On/Off, SpO2, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy.

• Defibrillator

Waveform: Biphasic.

Energy Display: Monitor display indicates both selected and delivered energy.

Charge Prompt Type: Voice and visual prompts.

Electrode Impedance Measurement Range: 0-250 ohms.

Charge Time: Less than 7 seconds with a new.

• ECG Monitoring

Patient Connection: 3-lead ECG cable, or 5- lead ECG cable. paddles.

Lead Selection: Displayed on monitor, paddles, 1, ll ll, AVR, AVL, AVF, V.

ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor.

Heart Rate: 20-300BPM.

Heart Rate Alarm: On/Off displayed on monitor, user- selectable.

Smart Alarms: Beeper/voice prompts indicate shockable rhythm.

• Battery

Type: Rechargeable, Ni- MH battery, 12v.

Operating Time: For a new, fully charged battery 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring Additional parameters will effect operating time with different functions.

• SpO2 Module

Measurement Range: 30~ 100%,± 2% between80%~90%, others ±5%.

Alarm Range: User set high limit and low limit.

Alarm Accuracy: ±10% within setting values.

Alarm time Accuracy: less than 12 sec.

• Recorder

Paper: 50mm thermal.

Speed: 12.5mm/sec, 25mm/sec, 50mm/sec. User- selectable 6-second delay.

Printing Method: High-resolution, thermal array print head.

Print-out Modes: Manual or automatic, user-configurable.

On/Off Control: Front panel and paddle.

Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge.

• AED Mode

AED Function: Auto analyze and charge x3 with programmable auto energy level selection, screen prompts, and voice prompts.

Shockable Rhythms: Ventricular fibrillation Ventricular tachycardia QRS complex wave duration.

Charge Control: Control on device front panel, press key on paddle.

• Manual Mode

Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules.

Synchronized Mode: Synchronizes defibrillator pulse to patient’s R-wave. “SYNC” message displayed on monitor.